Probe #5a9a1e320d of HP ProLiant DL580 G7

Log: dmidecode

# dmidecode 3.3 Getting SMBIOS data from sysfs. SMBIOS 2.7 present. 325 structures occupying 9239 bytes. Table at 0xBF7FD000. Handle 0x0000, DMI type 0, 24 bytes BIOS Information Vendor: HP Version: P65 Release Date: 05/03/2012 Address: 0xF0000 Runtime Size: 64 kB ROM Size: 8 MB Characteristics: PCI is supported PNP is supported BIOS is upgradeable BIOS shadowing is allowed ESCD support is available Boot from CD is supported Selectable boot is supported EDD is supported 5.25"/360 kB floppy services are supported (int 13h) 5.25"/1.2 MB floppy services are supported (int 13h) 3.5"/720 kB floppy services are supported (int 13h) Print screen service is supported (int 5h) 8042 keyboard services are supported (int 9h) Serial services are supported (int 14h) Printer services are supported (int 17h) CGA/mono video services are supported (int 10h) ACPI is supported USB legacy is supported BIOS boot specification is supported Function key-initiated network boot is supported Targeted content distribution is supported Firmware Revision: 1.94 Handle 0x0100, DMI type 1, 27 bytes System Information Manufacturer: HP Product Name: ProLiant DL580 G7 Version: Not Specified Serial Number: -- Wake-up Type: Power Switch SKU Number: 111222-333 Family: ProLiant Handle 0x0300, DMI type 3, 21 bytes Chassis Information Manufacturer: HP Type: Rack Mount Chassis Lock: Not Present Version: Not Specified Serial Number: -- Boot-up State: Safe Power Supply State: Safe Thermal State: Safe Security Status: Unknown OEM Information: 0x00000000 Height: 4 U Number Of Power Cords: 4 Contained Elements: 0 Handle 0x0400, DMI type 4, 42 bytes Processor Information Socket Designation: Proc 1 Type: Central Processor Family: Xeon Manufacturer: Intel ID: F2 06 02 00 FF FB EB BF Signature: Type 0, Family 6, Model 47, Stepping 2 Flags: FPU (Floating-point unit on-chip) VME (Virtual mode extension) DE (Debugging extension) PSE (Page size extension) TSC (Time stamp counter) MSR (Model specific registers) PAE (Physical address extension) MCE (Machine check exception) CX8 (CMPXCHG8 instruction supported) APIC (On-chip APIC hardware supported) SEP (Fast system call) MTRR (Memory type range registers) PGE (Page global enable) MCA (Machine check architecture) CMOV (Conditional move instruction supported) PAT (Page attribute table) PSE-36 (36-bit page size extension) CLFSH (CLFLUSH instruction supported) DS (Debug store) ACPI (ACPI supported) MMX (MMX technology supported) FXSR (FXSAVE and FXSTOR instructions supported) SSE (Streaming SIMD extensions) SSE2 (Streaming SIMD extensions 2) SS (Self-snoop) HTT (Multi-threading) TM (Thermal monitor supported) PBE (Pending break enabled) Version: Intel(R) Xeon(R) CPU E7- 4870 @ 2.40GHz Voltage: 1.4 V External Clock: 133 MHz Max Speed: 4800 MHz Current Speed: 2400 MHz Status: Populated, Enabled Upgrade: Socket LGA1567 L1 Cache Handle: 0x0710 L2 Cache Handle: 0x0720 L3 Cache Handle: 0x0730 Serial Number: -- Asset Tag: -- Part Number: Not Specified Core Count: 10 Core Enabled: 10 Thread Count: 20 Characteristics: 64-bit capable Multi-Core Hardware Thread Execute Protection Enhanced Virtualization Power/Performance Control Handle 0x0401, DMI type 4, 42 bytes Processor Information Socket Designation: Proc 2 Type: Central Processor Family: Xeon Manufacturer: Intel ID: F2 06 02 00 FF FB EB BF Signature: Type 0, Family 6, Model 47, Stepping 2 Flags: FPU (Floating-point unit on-chip) VME (Virtual mode extension) DE (Debugging extension) PSE (Page size extension) TSC (Time stamp counter) MSR (Model specific registers) PAE (Physical address extension) MCE (Machine check exception) CX8 (CMPXCHG8 instruction supported) APIC (On-chip APIC hardware supported) SEP (Fast system call) MTRR (Memory type range registers) PGE (Page global enable) MCA (Machine check architecture) CMOV (Conditional move instruction supported) PAT (Page attribute table) PSE-36 (36-bit page size extension) CLFSH (CLFLUSH instruction supported) DS (Debug store) ACPI (ACPI supported) MMX (MMX technology supported) FXSR (FXSAVE and FXSTOR instructions supported) SSE (Streaming SIMD extensions) SSE2 (Streaming SIMD extensions 2) SS (Self-snoop) HTT (Multi-threading) TM (Thermal monitor supported) PBE (Pending break enabled) Version: Intel(R) Xeon(R) CPU E7- 4870 @ 2.40GHz Voltage: 1.4 V External Clock: 133 MHz Max Speed: 4800 MHz Current Speed: 2400 MHz Status: Populated, Idle Upgrade: Socket LGA1567 L1 Cache Handle: 0x0711 L2 Cache Handle: 0x0721 L3 Cache Handle: 0x0731 Serial Number: -- Asset Tag: -- Part Number: Not Specified Core Count: 10 Core Enabled: 10 Thread Count: 20 Characteristics: 64-bit capable Multi-Core Hardware Thread Execute Protection Enhanced Virtualization Power/Performance Control Handle 0x0402, DMI type 4, 42 bytes Processor Information Socket Designation: Proc 3 Type: Central Processor Family: Xeon Manufacturer: Intel ID: F2 06 02 00 FF FB EB BF Signature: Type 0, Family 6, Model 47, Stepping 2 Flags: FPU (Floating-point unit on-chip) VME (Virtual mode extension) DE (Debugging extension) PSE (Page size extension) TSC (Time stamp counter) MSR (Model specific registers) PAE (Physical address extension) MCE (Machine check exception) CX8 (CMPXCHG8 instruction supported) APIC (On-chip APIC hardware supported) SEP (Fast system call) MTRR (Memory type range registers) PGE (Page global enable) MCA (Machine check architecture) CMOV (Conditional move instruction supported) PAT (Page attribute table) PSE-36 (36-bit page size extension) CLFSH (CLFLUSH instruction supported) DS (Debug store) ACPI (ACPI supported) MMX (MMX technology supported) FXSR (FXSAVE and FXSTOR instructions supported) SSE (Streaming SIMD extensions) SSE2 (Streaming SIMD extensions 2) SS (Self-snoop) HTT (Multi-threading) TM (Thermal monitor supported) PBE (Pending break enabled) Version: Intel(R) Xeon(R) CPU E7- 4870 @ 2.40GHz Voltage: 1.4 V External Clock: 133 MHz Max Speed: 4800 MHz Current Speed: 2400 MHz Status: Populated, Idle Upgrade: Socket LGA1567 L1 Cache Handle: 0x0712 L2 Cache Handle: 0x0722 L3 Cache Handle: 0x0732 Serial Number: -- Asset Tag: -- Part Number: Not Specified Core Count: 10 Core Enabled: 10 Thread Count: 20 Characteristics: 64-bit capable Multi-Core Hardware Thread Execute Protection Enhanced Virtualization Power/Performance Control Handle 0x0403, DMI type 4, 42 bytes Processor Information Socket Designation: Proc 4 Type: Central Processor Family: Xeon Manufacturer: Intel ID: F2 06 02 00 FF FB EB BF Signature: Type 0, Family 6, Model 47, Stepping 2 Flags: FPU (Floating-point unit on-chip) VME (Virtual mode extension) DE (Debugging extension) PSE (Page size extension) TSC (Time stamp counter) MSR (Model specific registers) PAE (Physical address extension) MCE (Machine check exception) CX8 (CMPXCHG8 instruction supported) APIC (On-chip APIC hardware supported) SEP (Fast system call) MTRR (Memory type range registers) PGE (Page global enable) MCA (Machine check architecture) CMOV (Conditional move instruction supported) PAT (Page attribute table) PSE-36 (36-bit page size extension) CLFSH (CLFLUSH instruction supported) DS (Debug store) ACPI (ACPI supported) MMX (MMX technology supported) FXSR (FXSAVE and FXSTOR instructions supported) SSE (Streaming SIMD extensions) SSE2 (Streaming SIMD extensions 2) SS (Self-snoop) HTT (Multi-threading) TM (Thermal monitor supported) PBE (Pending break enabled) Version: Intel(R) Xeon(R) CPU E7- 4870 @ 2.40GHz Voltage: 1.4 V External Clock: 133 MHz Max Speed: 4800 MHz Current Speed: 2400 MHz Status: Populated, Idle Upgrade: Socket LGA1567 L1 Cache Handle: 0x0713 L2 Cache Handle: 0x0723 L3 Cache Handle: 0x0733 Serial Number: -- Asset Tag: -- Part Number: Not Specified Core Count: 10 Core Enabled: 10 Thread Count: 20 Characteristics: 64-bit capable Multi-Core Hardware Thread Execute Protection Enhanced Virtualization Power/Performance Control Handle 0x0710, DMI type 7, 19 bytes Cache Information Socket Designation: Processor 1 Internal L1 Cache Configuration: Enabled, Not Socketed, Level 1 Operational Mode: Write Back Location: Internal Installed Size: 320 kB Maximum Size: 320 kB Supported SRAM Types: Burst Installed SRAM Type: Burst Speed: Unknown Error Correction Type: Single-bit ECC System Type: Data Associativity: 8-way Set-associative Handle 0x0711, DMI type 7, 19 bytes Cache Information Socket Designation: Processor 2 Internal L1 Cache Configuration: Enabled, Not Socketed, Level 1 Operational Mode: Write Back Location: Internal Installed Size: 320 kB Maximum Size: 320 kB Supported SRAM Types: Burst Installed SRAM Type: Burst Speed: Unknown Error Correction Type: Single-bit ECC System Type: Data Associativity: 8-way Set-associative Handle 0x0712, DMI type 7, 19 bytes Cache Information Socket Designation: Processor 3 Internal L1 Cache Configuration: Enabled, Not Socketed, Level 1 Operational Mode: Write Back Location: Internal Installed Size: 320 kB Maximum Size: 320 kB Supported SRAM Types: Burst Installed SRAM Type: Burst Speed: Unknown Error Correction Type: Single-bit ECC System Type: Data Associativity: 8-way Set-associative Handle 0x0713, DMI type 7, 19 bytes Cache Information Socket Designation: Processor 4 Internal L1 Cache Configuration: Enabled, Not Socketed, Level 1 Operational Mode: Write Back Location: Internal Installed Size: 320 kB Maximum Size: 320 kB Supported SRAM Types: Burst Installed SRAM Type: Burst Speed: Unknown Error Correction Type: Single-bit ECC System Type: Data Associativity: 8-way Set-associative Handle 0x0720, DMI type 7, 19 bytes Cache Information Socket Designation: Processor 1 Internal L2 Cache Configuration: Enabled, Not Socketed, Level 2 Operational Mode: Write Back Location: Internal Installed Size: 2560 kB Maximum Size: 2560 kB Supported SRAM Types: Burst Installed SRAM Type: Burst Speed: Unknown Error Correction Type: Single-bit ECC System Type: Unknown Associativity: 8-way Set-associative Handle 0x0721, DMI type 7, 19 bytes Cache Information Socket Designation: Processor 2 Internal L2 Cache Configuration: Enabled, Not Socketed, Level 2 Operational Mode: Write Back Location: Internal Installed Size: 2560 kB Maximum Size: 2560 kB Supported SRAM Types: Burst Installed SRAM Type: Burst Speed: Unknown Error Correction Type: Single-bit ECC System Type: Unknown Associativity: 8-way Set-associative Handle 0x0722, DMI type 7, 19 bytes Cache Information Socket Designation: Processor 3 Internal L2 Cache Configuration: Enabled, Not Socketed, Level 2 Operational Mode: Write Back Location: Internal Installed Size: 2560 kB Maximum Size: 2560 kB Supported SRAM Types: Burst Installed SRAM Type: Burst Speed: Unknown Error Correction Type: Single-bit ECC System Type: Unknown Associativity: 8-way Set-associative Handle 0x0723, DMI type 7, 19 bytes Cache Information Socket Designation: Processor 4 Internal L2 Cache Configuration: Enabled, Not Socketed, Level 2 Operational Mode: Write Back Location: Internal Installed Size: 2560 kB Maximum Size: 2560 kB Supported SRAM Types: Burst Installed SRAM Type: Burst Speed: Unknown Error Correction Type: Single-bit ECC System Type: Unknown Associativity: 8-way Set-associative Handle 0x0730, DMI type 7, 19 bytes Cache Information Socket Designation: Processor 1 Internal L3 Cache Configuration: Enabled, Not Socketed, Level 3 Operational Mode: Write Back Location: Internal Installed Size: 30 MB Maximum Size: 32 MB Supported SRAM Types: Burst Installed SRAM Type: Burst Speed: Unknown Error Correction Type: Single-bit ECC System Type: Unknown Associativity: 24-way Set-associative Handle 0x0731, DMI type 7, 19 bytes Cache Information Socket Designation: Processor 2 Internal L3 Cache Configuration: Enabled, Not Socketed, Level 3 Operational Mode: Write Back Location: Internal Installed Size: 30 MB Maximum Size: 32 MB Supported SRAM Types: Burst Installed SRAM Type: Burst Speed: Unknown Error Correction Type: Single-bit ECC System Type: Unknown Associativity: 24-way Set-associative Handle 0x0732, DMI type 7, 19 bytes Cache Information Socket Designation: Processor 3 Internal L3 Cache Configuration: Enabled, Not Socketed, Level 3 Operational Mode: Write Back Location: Internal Installed Size: 30 MB Maximum Size: 32 MB Supported SRAM Types: Burst Installed SRAM Type: Burst Speed: Unknown Error Correction Type: Single-bit ECC System Type: Unknown Associativity: 24-way Set-associative Handle 0x0733, DMI type 7, 19 bytes Cache Information Socket Designation: Processor 4 Internal L3 Cache Configuration: Enabled, Not Socketed, Level 3 Operational Mode: Write Back Location: Internal Installed Size: 30 MB Maximum Size: 32 MB Supported SRAM Types: Burst Installed SRAM Type: Burst Speed: Unknown Error Correction Type: Single-bit ECC System Type: Unknown Associativity: 24-way Set-associative Handle 0x0801, DMI type 8, 9 bytes Port Connector Information Internal Reference Designator: J7 Internal Connector Type: Access Bus (USB) External Reference Designator: USB Port 1 External Connector Type: Access Bus (USB) Port Type: USB Handle 0x0802, DMI type 8, 9 bytes Port Connector Information Internal Reference Designator: J7 Internal Connector Type: Access Bus (USB) External Reference Designator: USB Port 2 External Connector Type: Access Bus (USB) Port Type: USB Handle 0x0803, DMI type 8, 9 bytes Port Connector Information Internal Reference Designator: J3 Internal Connector Type: Access Bus (USB) External Reference Designator: USB Port 3 External Connector Type: Access Bus (USB) Port Type: USB Handle 0x0804, DMI type 8, 9 bytes Port Connector Information Internal Reference Designator: J1 Internal Connector Type: Access Bus (USB) External Reference Designator: USB Port 4 External Connector Type: Access Bus (USB) Port Type: USB Handle 0x0805, DMI type 8, 9 bytes Port Connector Information Internal Reference Designator: J28 Internal Connector Type: Access Bus (USB) External Reference Designator: USB Port 5 External Connector Type: Access Bus (USB) Port Type: USB Handle 0x0806, DMI type 8, 9 bytes Port Connector Information Internal Reference Designator: J29 Internal Connector Type: Access Bus (USB) External Reference Designator: USB Port 6 External Connector Type: Access Bus (USB) Port Type: USB Handle 0x0807, DMI type 8, 9 bytes Port Connector Information Internal Reference Designator: J27 Internal Connector Type: Access Bus (USB) External Reference Designator: USB Port 7 External Connector Type: Access Bus (USB) Port Type: USB Handle 0x0808, DMI type 8, 9 bytes Port Connector Information Internal Reference Designator: J12 Internal Connector Type: None External Reference Designator: Mouse Port External Connector Type: PS/2 Port Type: Mouse Port Handle 0x0809, DMI type 8, 9 bytes Port Connector Information Internal Reference Designator: J12 Internal Connector Type: None External Reference Designator: Keyboard Port External Connector Type: PS/2 Port Type: Keyboard Port Handle 0x080A, DMI type 8, 9 bytes Port Connector Information Internal Reference Designator: J14 Internal Connector Type: None External Reference Designator: Video Port External Connector Type: DB-15 female Port Type: Video Port Handle 0x080B, DMI type 8, 9 bytes Port Connector Information Internal Reference Designator: J4 Internal Connector Type: None External Reference Designator: Video Port External Connector Type: DB-15 female Port Type: Video Port Handle 0x080C, DMI type 8, 9 bytes Port Connector Information Internal Reference Designator: J14 Internal Connector Type: None External Reference Designator: COM Port External Connector Type: DB-9 male Port Type: Serial Port 16550A Compatible Handle 0x080D, DMI type 8, 9 bytes Port Connector Information Internal Reference Designator: J7 Internal Connector Type: None External Reference Designator: ILO NIC port External Connector Type: RJ-45 Port Type: Network Port Handle 0x080E, DMI type 8, 9 bytes Port Connector Information Internal Reference Designator: J17 Internal Connector Type: None External Reference Designator: NIC port 1 External Connector Type: RJ-45 Port Type: Network Port Handle 0x080F, DMI type 8, 9 bytes Port Connector Information Internal Reference Designator: J17 Internal Connector Type: None External Reference Designator: NIC port 2 External Connector Type: RJ-45 Port Type: Network Port Handle 0x0810, DMI type 8, 9 bytes Port Connector Information Internal Reference Designator: J22 Internal Connector Type: None External Reference Designator: NIC port 3 External Connector Type: RJ-45 Port Type: Network Port Handle 0x0811, DMI type 8, 9 bytes Port Connector Information Internal Reference Designator: J22 Internal Connector Type: None External Reference Designator: NIC port 4 External Connector Type: RJ-45 Port Type: Network Port Handle 0x0901, DMI type 9, 17 bytes System Slot Information Designation: PCI-E Slot 1 Type: x4 PCI Express x8 Current Usage: Available Length: Long ID: 1 Characteristics: 3.3 V is provided PME signal is supported Bus Address: 0000:81:00.0 Handle 0x0902, DMI type 9, 17 bytes System Slot Information Designation: PCI-E Slot 2 Type: x8 PCI Express 2 x16 Current Usage: Available Length: Long ID: 2 Characteristics: 3.3 V is provided PME signal is supported Bus Address: 0000:84:00.0 Handle 0x0903, DMI type 9, 17 bytes System Slot Information Designation: PCI-E Slot 3 Type: x8 PCI Express 2 x16 Current Usage: Available Length: Long ID: 3 Characteristics: 3.3 V is provided PME signal is supported Bus Address: 0000:87:00.0 Handle 0x0904, DMI type 9, 17 bytes System Slot Information Designation: PCI-E Slot 4 Type: x4 PCI Express 2 x8 Current Usage: Available Length: Long ID: 4 Characteristics: 3.3 V is provided PME signal is supported Bus Address: 0000:8a:00.0 Handle 0x0905, DMI type 9, 17 bytes System Slot Information Designation: PCI-E Slot 5 Type: x8 PCI Express 2 x16 Current Usage: Available Length: Long ID: 5 Characteristics: 3.3 V is provided PME signal is supported Bus Address: 0000:8d:00.0 Handle 0x0906, DMI type 9, 17 bytes System Slot Information Designation: PCI-E Slot 6 Type: x8 PCI Express 2 x16 Current Usage: Available Length: Long ID: 6 Characteristics: 3.3 V is provided PME signal is supported Bus Address: 0000:90:00.0 Handle 0x0907, DMI type 9, 17 bytes System Slot Information Designation: PCI-E Slot 7 Type: x4 PCI Express 2 x8 Current Usage: Available Length: Long ID: 7 Characteristics: 3.3 V is provided PME signal is supported Bus Address: 0000:05:00.0 Handle 0x0908, DMI type 9, 17 bytes System Slot Information Designation: PCI-E Slot 8 Type: x4 PCI Express 2 x8 Current Usage: Available Length: Long ID: 8 Characteristics: 3.3 V is provided PME signal is supported Bus Address: 0000:08:00.0 Handle 0x0909, DMI type 9, 17 bytes System Slot Information Designation: PCI-E Slot 9 Type: x8 PCI Express 2 x16 Current Usage: Available Length: Long ID: 9 Characteristics: 3.3 V is provided PME signal is supported Bus Address: 0000:0b:00.0 Handle 0x090A, DMI type 9, 17 bytes System Slot Information Designation: PCI-E Slot10 Type: x4 PCI Express 2 x8 Current Usage: Available Length: Long ID: 10 Characteristics: 3.3 V is provided PME signal is supported Bus Address: 0000:0e:00.0 Handle 0x090B, DMI type 9, 17 bytes System Slot Information Designation: PCI-E Slot11 Type: x8 PCI Express 2 x16 Current Usage: Available Length: Long ID: 11 Characteristics: 3.3 V is provided PME signal is supported Bus Address: 0000:11:00.0 Handle 0x0B00, DMI type 11, 5 bytes OEM Strings String 1: PSF: String 2: Product ID: 111222-333 Handle 0x1000, DMI type 16, 23 bytes Physical Memory Array Location: System Board Or Motherboard Use: System Memory Error Correction Type: Single-bit ECC Maximum Capacity: 512 GB Error Information Handle: Not Provided Number Of Devices: 16 Handle 0x1001, DMI type 16, 23 bytes Physical Memory Array Location: System Board Or Motherboard Use: System Memory Error Correction Type: Single-bit ECC Maximum Capacity: 512 GB Error Information Handle: Not Provided Number Of Devices: 16 Handle 0x1002, DMI type 16, 23 bytes Physical Memory Array Location: System Board Or Motherboard Use: System Memory Error Correction Type: Single-bit ECC Maximum Capacity: 512 GB Error Information Handle: Not Provided Number Of Devices: 16 Handle 0x1003, DMI type 16, 23 bytes Physical Memory Array Location: System Board Or Motherboard Use: System Memory Error Correction Type: Single-bit ECC Maximum Capacity: 512 GB Error Information Handle: Not Provided Number Of Devices: 16 Handle 0x1100, DMI type 17, 34 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 1 Locator: Board 1, DIMM 1A Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1101, DMI type 17, 34 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 2 Locator: Board 1, DIMM 2C Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1102, DMI type 17, 34 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 3 Locator: Board 1, DIMM 3B Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1103, DMI type 17, 34 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 4 Locator: Board 1, DIMM 4D Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1104, DMI type 17, 34 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 4 Locator: Board 1, DIMM 5D Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1105, DMI type 17, 34 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 3 Locator: Board 1, DIMM 6B Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1106, DMI type 17, 34 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 2 Locator: Board 1, DIMM 7C Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1107, DMI type 17, 34 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 1 Locator: Board 1, DIMM 8A Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1108, DMI type 17, 34 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 9 Locator: Board 2, DIMM 1A Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1109, DMI type 17, 34 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 10 Locator: Board 2, DIMM 2C Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x110A, DMI type 17, 34 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 11 Locator: Board 2, DIMM 3B Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x110B, DMI type 17, 34 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 12 Locator: Board 2, DIMM 4D Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x110C, DMI type 17, 34 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 12 Locator: Board 2, DIMM 5D Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x110D, DMI type 17, 34 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 11 Locator: Board 2, DIMM 6B Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x110E, DMI type 17, 34 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 10 Locator: Board 2, DIMM 7C Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x110F, DMI type 17, 34 bytes Memory Device Array Handle: 0x1000 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 9 Locator: Board 2, DIMM 8A Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1110, DMI type 17, 34 bytes Memory Device Array Handle: 0x1001 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 17 Locator: Board 3, DIMM 1A Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1111, DMI type 17, 34 bytes Memory Device Array Handle: 0x1001 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 18 Locator: Board 3, DIMM 2C Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1112, DMI type 17, 34 bytes Memory Device Array Handle: 0x1001 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 19 Locator: Board 3, DIMM 3B Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1113, DMI type 17, 34 bytes Memory Device Array Handle: 0x1001 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 20 Locator: Board 3, DIMM 4D Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1114, DMI type 17, 34 bytes Memory Device Array Handle: 0x1001 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 20 Locator: Board 3, DIMM 5D Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1115, DMI type 17, 34 bytes Memory Device Array Handle: 0x1001 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 19 Locator: Board 3, DIMM 6B Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1116, DMI type 17, 34 bytes Memory Device Array Handle: 0x1001 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 18 Locator: Board 3, DIMM 7C Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1117, DMI type 17, 34 bytes Memory Device Array Handle: 0x1001 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 17 Locator: Board 3, DIMM 8A Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1333 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1118, DMI type 17, 34 bytes Memory Device Array Handle: 0x1001 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 25 Locator: Board 4, DIMM 1A Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1119, DMI type 17, 34 bytes Memory Device Array Handle: 0x1001 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 26 Locator: Board 4, DIMM 2C Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x111A, DMI type 17, 34 bytes Memory Device Array Handle: 0x1001 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 27 Locator: Board 4, DIMM 3B Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x111B, DMI type 17, 34 bytes Memory Device Array Handle: 0x1001 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 28 Locator: Board 4, DIMM 4D Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x111C, DMI type 17, 34 bytes Memory Device Array Handle: 0x1001 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 28 Locator: Board 4, DIMM 5D Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x111D, DMI type 17, 34 bytes Memory Device Array Handle: 0x1001 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 27 Locator: Board 4, DIMM 6B Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x111E, DMI type 17, 34 bytes Memory Device Array Handle: 0x1001 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 26 Locator: Board 4, DIMM 7C Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x111F, DMI type 17, 34 bytes Memory Device Array Handle: 0x1001 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: 16 GB Form Factor: FB-DIMM Set: 25 Locator: Board 4, DIMM 8A Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: 1600 MT/s Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: 2 Configured Memory Speed: 1067 MT/s Handle 0x1120, DMI type 17, 34 bytes Memory Device Array Handle: 0x1002 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 33 Locator: Board 5, DIMM 1A Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1121, DMI type 17, 34 bytes Memory Device Array Handle: 0x1002 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 34 Locator: Board 5, DIMM 2C Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1122, DMI type 17, 34 bytes Memory Device Array Handle: 0x1002 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 35 Locator: Board 5, DIMM 3B Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1123, DMI type 17, 34 bytes Memory Device Array Handle: 0x1002 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 36 Locator: Board 5, DIMM 4D Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1124, DMI type 17, 34 bytes Memory Device Array Handle: 0x1002 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 36 Locator: Board 5, DIMM 5D Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1125, DMI type 17, 34 bytes Memory Device Array Handle: 0x1002 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 35 Locator: Board 5, DIMM 6B Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1126, DMI type 17, 34 bytes Memory Device Array Handle: 0x1002 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 34 Locator: Board 5, DIMM 7C Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1127, DMI type 17, 34 bytes Memory Device Array Handle: 0x1002 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 33 Locator: Board 5, DIMM 8A Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1128, DMI type 17, 34 bytes Memory Device Array Handle: 0x1002 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 41 Locator: Board 6, DIMM 1A Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1129, DMI type 17, 34 bytes Memory Device Array Handle: 0x1002 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 42 Locator: Board 6, DIMM 2C Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x112A, DMI type 17, 34 bytes Memory Device Array Handle: 0x1002 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 43 Locator: Board 6, DIMM 3B Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x112B, DMI type 17, 34 bytes Memory Device Array Handle: 0x1002 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 44 Locator: Board 6, DIMM 4D Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x112C, DMI type 17, 34 bytes Memory Device Array Handle: 0x1002 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 44 Locator: Board 6, DIMM 5D Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x112D, DMI type 17, 34 bytes Memory Device Array Handle: 0x1002 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 43 Locator: Board 6, DIMM 6B Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x112E, DMI type 17, 34 bytes Memory Device Array Handle: 0x1002 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 42 Locator: Board 6, DIMM 7C Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x112F, DMI type 17, 34 bytes Memory Device Array Handle: 0x1002 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 41 Locator: Board 6, DIMM 8A Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1130, DMI type 17, 34 bytes Memory Device Array Handle: 0x1003 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 49 Locator: Board 7, DIMM 1A Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1131, DMI type 17, 34 bytes Memory Device Array Handle: 0x1003 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 50 Locator: Board 7, DIMM 2C Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1132, DMI type 17, 34 bytes Memory Device Array Handle: 0x1003 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 51 Locator: Board 7, DIMM 3B Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1133, DMI type 17, 34 bytes Memory Device Array Handle: 0x1003 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 52 Locator: Board 7, DIMM 4D Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1134, DMI type 17, 34 bytes Memory Device Array Handle: 0x1003 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 52 Locator: Board 7, DIMM 5D Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1135, DMI type 17, 34 bytes Memory Device Array Handle: 0x1003 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 51 Locator: Board 7, DIMM 6B Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1136, DMI type 17, 34 bytes Memory Device Array Handle: 0x1003 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 50 Locator: Board 7, DIMM 7C Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1137, DMI type 17, 34 bytes Memory Device Array Handle: 0x1003 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 49 Locator: Board 7, DIMM 8A Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1138, DMI type 17, 34 bytes Memory Device Array Handle: 0x1003 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 57 Locator: Board 8, DIMM 1A Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1139, DMI type 17, 34 bytes Memory Device Array Handle: 0x1003 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 58 Locator: Board 8, DIMM 2C Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x113A, DMI type 17, 34 bytes Memory Device Array Handle: 0x1003 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 59 Locator: Board 8, DIMM 3B Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x113B, DMI type 17, 34 bytes Memory Device Array Handle: 0x1003 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 60 Locator: Board 8, DIMM 4D Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x113C, DMI type 17, 34 bytes Memory Device Array Handle: 0x1003 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 60 Locator: Board 8, DIMM 5D Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x113D, DMI type 17, 34 bytes Memory Device Array Handle: 0x1003 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 59 Locator: Board 8, DIMM 6B Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x113E, DMI type 17, 34 bytes Memory Device Array Handle: 0x1003 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 58 Locator: Board 8, DIMM 7C Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x113F, DMI type 17, 34 bytes Memory Device Array Handle: 0x1003 Error Information Handle: Not Provided Total Width: 72 bits Data Width: 64 bits Size: No Module Installed Form Factor: FB-DIMM Set: 57 Locator: Board 8, DIMM 8A Bank Locator: Not Specified Type: DDR3 Type Detail: Synchronous Speed: Unknown Manufacturer: Not Specified Serial Number: -- Asset Tag: -- Part Number: Not Specified Rank: Unknown Configured Memory Speed: Unknown Handle 0x1300, DMI type 19, 31 bytes Memory Array Mapped Address Starting Address: 0x00000000000 Ending Address: 0x000BFFFFFFF Range Size: 3 GB Physical Array Handle: 0x1000 Partition Width: 1 Handle 0x1301, DMI type 19, 31 bytes Memory Array Mapped Address Starting Address: 0x00100000000 Ending Address: 0x0403FFFFFFF Range Size: 253 GB Physical Array Handle: 0x1000 Partition Width: 1 Handle 0x1302, DMI type 19, 31 bytes Memory Array Mapped Address Starting Address: 0x04040000000 Ending Address: 0x0803FFFFFFF Range Size: 256 GB Physical Array Handle: 0x1001 Partition Width: 1 Handle 0x1303, DMI type 218, 31 bytes OEM-specific Type Header and Data: DA 1F 03 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Handle 0x1304, DMI type 218, 31 bytes OEM-specific Type Header and Data: DA 1F 04 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Handle 0x1305, DMI type 218, 31 bytes OEM-specific Type Header and Data: DA 1F 05 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Handle 0x1306, DMI type 218, 31 bytes OEM-specific Type Header and Data: DA 1F 06 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Handle 0x1307, DMI type 218, 31 bytes OEM-specific Type Header and Data: DA 1F 07 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Handle 0x1308, DMI type 218, 31 bytes OEM-specific Type Header and Data: DA 1F 08 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Handle 0x1309, DMI type 218, 31 bytes OEM-specific Type Header and Data: DA 1F 09 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Handle 0x130A, DMI type 218, 31 bytes OEM-specific Type Header and Data: DA 1F 0A 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Handle 0x130B, DMI type 218, 31 bytes OEM-specific Type Header and Data: DA 1F 0B 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Handle 0x130C, DMI type 218, 31 bytes OEM-specific Type Header and Data: DA 1F 0C 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Handle 0x130D, DMI type 218, 31 bytes OEM-specific Type Header and Data: DA 1F 0D 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Handle 0x130E, DMI type 218, 31 bytes OEM-specific Type Header and Data: DA 1F 0E 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Handle 0x130F, DMI type 218, 31 bytes OEM-specific Type Header and Data: DA 1F 0F 13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Handle 0x2000, DMI type 32, 11 bytes System Boot Information Status: No errors detected Handle 0x2600, DMI type 38, 18 bytes IPMI Device Information Interface Type: KCS (Keyboard Control Style) Specification Version: 2.0 I2C Slave Address: 0x10 NV Storage Device: Not Present Base Address: 0x0000000000000CA2 (I/O) Register Spacing: Successive Byte Boundaries Handle 0x2700, DMI type 39, 22 bytes System Power Supply Power Unit Group: 1 Location: Not Specified Name: Power Supply 1 Manufacturer: HP Serial Number: -- Asset Tag: -- Model Part Number: 500172-B21 Revision: Not Specified Max Power Capacity: 1200 W Status: Present, Unknown Type: Switching Input Voltage Range Switching: Auto-switch Plugged: Yes Hot Replaceable: Yes Handle 0x2701, DMI type 39, 22 bytes System Power Supply Power Unit Group: 1 Location: Not Specified Name: Power Supply 2 Manufacturer: HP Serial Number: -- Asset Tag: -- Model Part Number: 500172-B21 Revision: Not Specified Max Power Capacity: 1200 W Status: Present, Unknown Type: Switching Input Voltage Range Switching: Auto-switch Plugged: Yes Hot Replaceable: Yes Handle 0x2702, DMI type 39, 22 bytes System Power Supply Power Unit Group: 1 Location: Not Specified Name: Power Supply 3 Manufacturer: HP Serial Number: -- Asset Tag: -- Model Part Number: 500172-B21 Revision: Not Specified Max Power Capacity: 1200 W Status: Present, Unknown Type: Switching Input Voltage Range Switching: Auto-switch Plugged: Yes Hot Replaceable: Yes Handle 0x2703, DMI type 39, 22 bytes System Power Supply Power Unit Group: 1 Location: Not Specified Name: Power Supply 4 Manufacturer: HP Serial Number: -- Asset Tag: -- Model Part Number: 500172-B21 Revision: Not Specified Max Power Capacity: 1200 W Status: Present, Unknown Type: Switching Input Voltage Range Switching: Auto-switch Plugged: Yes Hot Replaceable: Yes Handle 0xC101, DMI type 193, 28 bytes OEM-specific Type Header and Data: C1 1C 01 C1 01 01 02 03 04 05 10 10 10 11 10 10 06 06 00 00 00 00 06 07 08 09 0A 0B Strings: 05/03/2012 01/18/2011 1.6 SPI Board PAL MainIO Board PAL CPU Board PAL Standard PCIe Board PAL Handle 0xC200, DMI type 194, 5 bytes OEM-specific Type Header and Data: C2 05 00 C2 01 Handle 0xC300, DMI type 195, 5 bytes OEM-specific Type Header and Data: C3 05 00 C3 01 Strings: $0E1107B8 Handle 0xC400, DMI type 196, 5 bytes OEM-specific Type Header and Data: C4 05 00 C4 00 Handle 0xC500, DMI type 197, 12 bytes OEM-specific Type Header and Data: C5 0C 00 C5 00 04 00 01 FF 01 82 00 Handle 0xC501, DMI type 197, 12 bytes OEM-specific Type Header and Data: C5 0C 01 C5 01 04 40 00 FF 02 82 00 Handle 0xC502, DMI type 197, 12 bytes OEM-specific Type Header and Data: C5 0C 02 C5 02 04 80 00 FF 03 82 00 Handle 0xC503, DMI type 197, 12 bytes OEM-specific Type Header and Data: C5 0C 03 C5 03 04 C0 00 FF 04 82 00 Handle 0xC700, DMI type 199, 76 bytes OEM-specific Type Header and Data: C7 4C 00 C7 36 00 00 00 12 20 12 04 F2 06 02 00 08 00 00 00 10 20 13 10 F1 06 02 00 09 00 00 00 12 20 16 04 E6 06 02 00 16 00 FF FF 09 20 28 09 E5 06 02 00 26 65 48 E4 09 20 30 09 E5 06 02 00 07 65 48 E4 09 20 09 12 E6 06 02 00 Handle 0xD300, DMI type 211, 7 bytes OEM-specific Type Header and Data: D3 07 00 D3 00 04 44 Handle 0xD301, DMI type 211, 7 bytes OEM-specific Type Header and Data: D3 07 01 D3 01 04 44 Handle 0xD302, DMI type 211, 7 bytes OEM-specific Type Header and Data: D3 07 02 D3 02 04 44 Handle 0xD303, DMI type 211, 7 bytes OEM-specific Type Header and Data: D3 07 03 D3 03 04 44 Handle 0xC600, DMI type 198, 11 bytes OEM-specific Type Header and Data: C6 0B 00 C6 17 00 00 01 3C 00 01 Handle 0xCD00, DMI type 205, 22 bytes OEM-specific Type Header and Data: CD 16 00 CD 01 01 46 41 54 78 00 00 E0 FF 00 00 00 00 00 00 0D 00 Handle 0xCA00, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 00 CA 00 11 01 01 FF Handle 0xCA01, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 01 CA 01 11 01 02 FF Handle 0xCA02, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 02 CA 02 11 01 03 FF Handle 0xCA03, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 03 CA 03 11 01 04 FF Handle 0xCA04, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 04 CA 04 11 01 05 FF Handle 0xCA05, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 05 CA 05 11 01 06 FF Handle 0xCA06, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 06 CA 06 11 01 07 FF Handle 0xCA07, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 07 CA 07 11 01 08 FF Handle 0xCA08, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 08 CA 08 11 02 01 FF Handle 0xCA09, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 09 CA 09 11 02 02 FF Handle 0xCA0A, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 0A CA 0A 11 02 03 FF Handle 0xCA0B, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 0B CA 0B 11 02 04 FF Handle 0xCA0C, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 0C CA 0C 11 02 05 FF Handle 0xCA0D, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 0D CA 0D 11 02 06 FF Handle 0xCA0E, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 0E CA 0E 11 02 07 FF Handle 0xCA0F, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 0F CA 0F 11 02 08 FF Handle 0xCA10, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 10 CA 10 11 03 01 FF Handle 0xCA11, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 11 CA 11 11 03 02 FF Handle 0xCA12, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 12 CA 12 11 03 03 FF Handle 0xCA13, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 13 CA 13 11 03 04 FF Handle 0xCA14, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 14 CA 14 11 03 05 FF Handle 0xCA15, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 15 CA 15 11 03 06 FF Handle 0xCA16, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 16 CA 16 11 03 07 FF Handle 0xCA17, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 17 CA 17 11 03 08 FF Handle 0xCA18, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 18 CA 18 11 04 01 FF Handle 0xCA19, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 19 CA 19 11 04 02 FF Handle 0xCA1A, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 1A CA 1A 11 04 03 FF Handle 0xCA1B, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 1B CA 1B 11 04 04 FF Handle 0xCA1C, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 1C CA 1C 11 04 05 FF Handle 0xCA1D, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 1D CA 1D 11 04 06 FF Handle 0xCA1E, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 1E CA 1E 11 04 07 FF Handle 0xCA1F, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 1F CA 1F 11 04 08 FF Handle 0xCA20, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 20 CA 20 11 05 01 FF Handle 0xCA21, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 21 CA 21 11 05 02 FF Handle 0xCA22, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 22 CA 22 11 05 03 FF Handle 0xCA23, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 23 CA 23 11 05 04 FF Handle 0xCA24, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 24 CA 24 11 05 05 FF Handle 0xCA25, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 25 CA 25 11 05 06 FF Handle 0xCA26, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 26 CA 26 11 05 07 FF Handle 0xCA27, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 27 CA 27 11 05 08 FF Handle 0xCA28, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 28 CA 28 11 06 01 FF Handle 0xCA29, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 29 CA 29 11 06 02 FF Handle 0xCA2A, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 2A CA 2A 11 06 03 FF Handle 0xCA2B, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 2B CA 2B 11 06 04 FF Handle 0xCA2C, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 2C CA 2C 11 06 05 FF Handle 0xCA2D, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 2D CA 2D 11 06 06 FF Handle 0xCA2E, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 2E CA 2E 11 06 07 FF Handle 0xCA2F, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 2F CA 2F 11 06 08 FF Handle 0xCA30, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 30 CA 30 11 07 01 FF Handle 0xCA31, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 31 CA 31 11 07 02 FF Handle 0xCA32, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 32 CA 32 11 07 03 FF Handle 0xCA33, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 33 CA 33 11 07 04 FF Handle 0xCA34, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 34 CA 34 11 07 05 FF Handle 0xCA35, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 35 CA 35 11 07 06 FF Handle 0xCA36, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 36 CA 36 11 07 07 FF Handle 0xCA37, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 37 CA 37 11 07 08 FF Handle 0xCA38, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 38 CA 38 11 08 01 FF Handle 0xCA39, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 39 CA 39 11 08 02 FF Handle 0xCA3A, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 3A CA 3A 11 08 03 FF Handle 0xCA3B, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 3B CA 3B 11 08 04 FF Handle 0xCA3C, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 3C CA 3C 11 08 05 FF Handle 0xCA3D, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 3D CA 3D 11 08 06 FF Handle 0xCA3E, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 3E CA 3E 11 08 07 FF Handle 0xCA3F, DMI type 202, 9 bytes OEM-specific Type Header and Data: CA 09 3F CA 3F 11 08 08 FF Handle 0xD100, DMI type 209, 36 bytes HP BIOS PXE NIC PCI and MAC Information NIC 1: PCI device 04:00.0, MAC address 6C:3B:E5:A2:DD:30 NIC 2: PCI device 04:00.1, MAC address 6C:3B:E5:A2:DD:31 NIC 3: PCI device 04:00.2, MAC address 6C:3B:E5:A2:DD:32 NIC 4: PCI device 04:00.3, MAC address 6C:3B:E5:A2:DD:33 Handle 0xD400, DMI type 212, 24 bytes HP 64-bit CRU Information Signature: 0x55524324 ($CRU) Physical Address: 0x00000000fff05c00 Length: 0x00004000 Handle 0xD700, DMI type 215, 6 bytes OEM-specific Type Header and Data: D7 06 00 D7 00 05 Handle 0xDB00, DMI type 219, 8 bytes HP ProLiant Information Power Features: 0x00000bdf Handle 0xDF00, DMI type 223, 7 bytes OEM-specific Type Header and Data: DF 07 00 DF 66 46 70 Handle 0xE000, DMI type 224, 5 bytes OEM-specific Type Header and Data: E0 05 00 E0 00 Handle 0xE200, DMI type 226, 21 bytes OEM-specific Type Header and Data: E2 15 00 E2 31 31 31 32 32 32 00 00 00 00 00 00 00 00 00 00 01 Strings: Handle 0xE300, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 00 E3 00 04 00 11 07 A0 01 00 Handle 0xE301, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 01 E3 00 04 01 11 07 A2 01 00 Handle 0xE302, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 02 E3 00 04 02 11 07 A4 01 00 Handle 0xE303, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 03 E3 00 04 03 11 07 A6 01 00 Handle 0xE304, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 04 E3 00 04 04 11 07 AE 01 00 Handle 0xE305, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 05 E3 00 04 05 11 07 AC 01 00 Handle 0xE306, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 06 E3 00 04 06 11 07 AA 01 00 Handle 0xE307, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 07 E3 00 04 07 11 07 A8 01 00 Handle 0xE308, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 08 E3 00 04 08 11 08 A0 01 01 Handle 0xE309, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 09 E3 00 04 09 11 08 A2 01 01 Handle 0xE30A, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 0A E3 00 04 0A 11 08 A4 01 01 Handle 0xE30B, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 0B E3 00 04 0B 11 08 A6 01 01 Handle 0xE30C, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 0C E3 00 04 0C 11 08 AE 01 01 Handle 0xE30D, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 0D E3 00 04 0D 11 08 AC 01 01 Handle 0xE30E, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 0E E3 00 04 0E 11 08 AA 01 01 Handle 0xE30F, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 0F E3 00 04 0F 11 08 A8 01 01 Handle 0xE310, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 10 E3 01 04 10 11 09 A0 01 02 Handle 0xE311, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 11 E3 01 04 11 11 09 A2 01 02 Handle 0xE312, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 12 E3 01 04 12 11 09 A4 01 02 Handle 0xE313, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 13 E3 01 04 13 11 09 A6 01 02 Handle 0xE314, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 14 E3 01 04 14 11 09 AE 01 02 Handle 0xE315, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 15 E3 01 04 15 11 09 AC 01 02 Handle 0xE316, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 16 E3 01 04 16 11 09 AA 01 02 Handle 0xE317, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 17 E3 01 04 17 11 09 A8 01 02 Handle 0xE318, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 18 E3 01 04 18 11 0A A0 01 03 Handle 0xE319, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 19 E3 01 04 19 11 0A A2 01 03 Handle 0xE31A, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 1A E3 01 04 1A 11 0A A4 01 03 Handle 0xE31B, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 1B E3 01 04 1B 11 0A A6 01 03 Handle 0xE31C, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 1C E3 01 04 1C 11 0A AE 01 03 Handle 0xE31D, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 1D E3 01 04 1D 11 0A AC 01 03 Handle 0xE31E, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 1E E3 01 04 1E 11 0A AA 01 03 Handle 0xE31F, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 1F E3 01 04 1F 11 0A A8 01 03 Handle 0xE320, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 20 E3 02 04 20 11 0B A0 01 04 Handle 0xE321, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 21 E3 02 04 21 11 0B A2 01 04 Handle 0xE322, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 22 E3 02 04 22 11 0B A4 01 04 Handle 0xE323, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 23 E3 02 04 23 11 0B A6 01 04 Handle 0xE324, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 24 E3 02 04 24 11 0B AE 01 04 Handle 0xE325, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 25 E3 02 04 25 11 0B AC 01 04 Handle 0xE326, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 26 E3 02 04 26 11 0B AA 01 04 Handle 0xE327, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 27 E3 02 04 27 11 0B A8 01 04 Handle 0xE328, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 28 E3 02 04 28 11 0C A0 01 05 Handle 0xE329, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 29 E3 02 04 29 11 0C A2 01 05 Handle 0xE32A, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 2A E3 02 04 2A 11 0C A4 01 05 Handle 0xE32B, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 2B E3 02 04 2B 11 0C A6 01 05 Handle 0xE32C, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 2C E3 02 04 2C 11 0C AE 01 05 Handle 0xE32D, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 2D E3 02 04 2D 11 0C AC 01 05 Handle 0xE32E, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 2E E3 02 04 2E 11 0C AA 01 05 Handle 0xE32F, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 2F E3 02 04 2F 11 0C A8 01 05 Handle 0xE330, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 30 E3 03 04 30 11 0D A0 01 06 Handle 0xE331, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 31 E3 03 04 31 11 0D A2 01 06 Handle 0xE332, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 32 E3 03 04 32 11 0D A4 01 06 Handle 0xE333, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 33 E3 03 04 33 11 0D A6 01 06 Handle 0xE334, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 34 E3 03 04 34 11 0D AE 01 06 Handle 0xE335, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 35 E3 03 04 35 11 0D AC 01 06 Handle 0xE336, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 36 E3 03 04 36 11 0D AA 01 06 Handle 0xE337, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 37 E3 03 04 37 11 0D A8 01 06 Handle 0xE338, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 38 E3 03 04 38 11 0E A0 01 07 Handle 0xE339, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 39 E3 03 04 39 11 0E A2 01 07 Handle 0xE33A, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 3A E3 03 04 3A 11 0E A4 01 07 Handle 0xE33B, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 3B E3 03 04 3B 11 0E A6 01 07 Handle 0xE33C, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 3C E3 03 04 3C 11 0E AE 01 07 Handle 0xE33D, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 3D E3 03 04 3D 11 0E AC 01 07 Handle 0xE33E, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 3E E3 03 04 3E 11 0E AA 01 07 Handle 0xE33F, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 3F E3 03 04 3F 11 0E A8 01 07 Handle 0xE340, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 40 E3 00 04 00 11 07 C0 02 00 Handle 0xE341, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 41 E3 00 04 00 11 07 C2 02 00 Handle 0xE342, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 42 E3 00 04 08 11 08 C0 02 01 Handle 0xE343, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 43 E3 00 04 08 11 08 C2 02 01 Handle 0xE344, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 44 E3 01 04 10 11 09 C0 02 02 Handle 0xE345, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 45 E3 01 04 10 11 09 C2 02 02 Handle 0xE346, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 46 E3 01 04 18 11 0A C0 02 03 Handle 0xE347, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 47 E3 01 04 18 11 0A C2 02 03 Handle 0xE348, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 48 E3 02 04 20 11 0B B0 02 04 Handle 0xE349, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 49 E3 02 04 20 11 0B B2 02 04 Handle 0xE34A, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 4A E3 02 04 28 11 0C B0 02 05 Handle 0xE34B, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 4B E3 02 04 28 11 0C B2 02 05 Handle 0xE34C, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 4C E3 03 04 30 11 0D B0 02 06 Handle 0xE34D, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 4D E3 03 04 30 11 0D B2 02 06 Handle 0xE34E, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 4E E3 03 04 38 11 0E B0 02 07 Handle 0xE34F, DMI type 227, 12 bytes OEM-specific Type Header and Data: E3 0C 4F E3 03 04 38 11 0E B2 02 07 Handle 0xE400, DMI type 228, 14 bytes OEM-specific Type Header and Data: E4 0E 00 E4 00 00 00 00 00 00 00 FF 00 00 Handle 0xE401, DMI type 228, 14 bytes OEM-specific Type Header and Data: E4 0E 01 E4 01 00 00 00 00 00 00 FF 00 00 Handle 0xE402, DMI type 228, 14 bytes OEM-specific Type Header and Data: E4 0E 02 E4 02 00 00 00 00 00 00 FF 00 00 Handle 0xE403, DMI type 228, 14 bytes OEM-specific Type Header and Data: E4 0E 03 E4 03 00 00 00 00 00 00 FF 00 00 Handle 0xE404, DMI type 228, 14 bytes OEM-specific Type Header and Data: E4 0E 04 E4 04 00 00 00 00 00 00 FF 01 00 Handle 0xE405, DMI type 228, 14 bytes OEM-specific Type Header and Data: E4 0E 05 E4 05 00 00 00 00 00 00 FF 00 00 Handle 0xE406, DMI type 228, 14 bytes OEM-specific Type Header and Data: E4 0E 06 E4 06 06 00 00 00 00 00 FF 00 00 Handle 0xE407, DMI type 228, 14 bytes OEM-specific Type Header and Data: E4 0E 07 E4 07 05 E0 00 07 04 30 06 00 00 Handle 0xE408, DMI type 228, 14 bytes OEM-specific Type Header and Data: E4 0E 08 E4 08 05 E0 00 07 05 30 06 00 00 Handle 0xE409, DMI type 228, 14 bytes OEM-specific Type Header and Data: E4 0E 09 E4 09 05 E0 00 07 04 31 06 00 00 Handle 0xE40A, DMI type 228, 14 bytes OEM-specific Type Header and Data: E4 0E 0A E4 0A 05 E0 00 07 05 31 06 00 00 Handle 0xE40B, DMI type 228, 14 bytes OEM-specific Type Header and Data: E4 0E 0B E4 0B 05 E0 00 07 04 32 06 00 00 Handle 0xE40C, DMI type 228, 14 bytes OEM-specific Type Header and Data: E4 0E 0C E4 0C 05 E0 00 07 05 32 06 00 00 Handle 0xE40D, DMI type 228, 14 bytes OEM-specific Type Header and Data: E4 0E 0D E4 0D 05 E0 00 07 04 33 06 00 00 Handle 0xE40E, DMI type 228, 14 bytes OEM-specific Type Header and Data: E4 0E 0E E4 0E 05 E0 00 07 05 33 06 00 00 Handle 0xE500, DMI type 229, 20 bytes OEM-specific Type Header and Data: E5 14 00 E5 24 48 44 44 00 E0 63 BF 00 00 00 00 00 20 00 00 Handle 0xE600, DMI type 230, 11 bytes OEM-specific Type Header and Data: E6 0B 00 E6 00 27 01 02 02 03 A0 Strings: LTEON 12 Handle 0xE601, DMI type 230, 11 bytes OEM-specific Type Header and Data: E6 0B 01 E6 01 27 01 02 02 03 A2 Strings: LTEON 12 Handle 0xE602, DMI type 230, 11 bytes OEM-specific Type Header and Data: E6 0B 02 E6 02 27 01 02 02 03 A8 Strings: LTEON 11 Handle 0xE603, DMI type 230, 11 bytes OEM-specific Type Header and Data: E6 0B 03 E6 03 27 01 02 02 03 AA Strings: LTEON 11 Handle 0x7F00, DMI type 127, 4 bytes End Of Table


Hardware for Linux and BSD

GitHub