/dev/sda
=== START OF INFORMATION SECTION ===
Device Model: TOSHIBA MK8037GSX
Serial Number: --
Firmware Version: DL232C
User Capacity: 80 026 361 856 bytes [80,0 GB]
Sector Size: 512 bytes logical/physical
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Thu Dec 3 20:02:00 2015 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 25) The self-test routine was aborted by
the host.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x51) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 39) minutes.
SCT capabilities: (0x0001) SCT Status supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 100 100 050 - 0
2 Throughput_Performance POS--- 100 100 050 - 0
3 Spin_Up_Time PO---- 100 100 002 - 1136
4 Start_Stop_Count -O--CK 100 100 000 - 4241
5 Reallocated_Sector_Ct PO--CK 100 100 050 - 21
7 Seek_Error_Rate POSR-- 100 100 050 - 0
8 Seek_Time_Performance P-S--- 100 100 050 - 0
9 Power_On_Hours -O--CK 057 057 000 - 17315
10 Spin_Retry_Count PO--C- 184 100 030 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 3767
187 Reported_Uncorrect -O--CK 001 001 000 - 119
188 Command_Timeout -O--CK 100 099 000 - 4
189 High_Fly_Writes -O-RCK 100 100 001 - 0
190 Airflow_Temperature_Cel -O---K 056 044 045 Past 44 (Min/Max 44/46)
191 G-Sense_Error_Rate -O--CK 100 100 000 - 16898
192 Power-Off_Retract_Count -O--CK 100 100 000 - 32309741
193 Load_Cycle_Count -O--CK 059 059 000 - 418411
194 Temperature_Celsius -O---K 100 100 000 - 44 (Min/Max 5/56)
196 Reallocated_Event_Count -O--CK 100 100 000 - 21
197 Current_Pending_Sector -O--C- 100 100 000 - 2
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 253 000 - 0
220 Disk_Shift -O---- 100 100 000 - 47
222 Loaded_Hours -O--CK 066 066 000 - 13895
223 Load_Retry_Count -O--CK 100 100 000 - 0
224 Load_Friction -O---K 100 100 000 - 0
226 Load-in_Time -OS--K 100 100 000 - 336
240 Head_Flying_Hours P----- 100 100 001 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 64 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x11 GPL R/O 1 SATA Phy Event Counters
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
Device Error Count: 120
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 120 [119] occurred at disk power-on lifetime: 11948 hours (497 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 1f 00 00 00 48 aa b0 40 00
Error: UNC 31 sectors at LBA = 0x0048aab0 = 4762288
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 20 4b be f2 48 aa af 40 00 00:25:33.734 READ DMA
c8 00 00 00 01 00 00 00 4b be f2 43 00 00:25:33.258 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 00:25:33.258 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 00:25:33.258 READ DMA
c8 00 00 1f 01 48 aa b0 00 00 00 40 00 00:25:33.249 READ DMA
Error 119 [118] occurred at disk power-on lifetime: 11948 hours (497 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 1f 00 00 00 48 aa b0 40 00
Error: UNC 31 sectors at LBA = 0x0048aab0 = 4762288
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 20 4b be f2 48 aa af 40 00 00:25:29.593 READ DMA
c8 00 00 00 01 00 00 00 4b be f2 43 00 00:25:29.114 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 00:25:29.114 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 00:25:29.113 READ DMA
c8 00 00 1f 01 48 aa b0 00 00 00 40 00 00:25:29.105 READ DMA
Error 118 [117] occurred at disk power-on lifetime: 11948 hours (497 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 1f 00 00 00 48 aa b0 40 00
Error: UNC 31 sectors at LBA = 0x0048aab0 = 4762288
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 20 4b be f2 48 aa af 40 00 00:25:25.453 READ DMA
c8 00 00 00 01 00 00 00 4b be f2 43 00 00:25:24.970 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 00:25:24.969 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 00:25:24.969 READ DMA
c8 00 00 1f 01 48 aa b0 00 00 00 40 00 00:25:24.960 READ DMA
Error 117 [116] occurred at disk power-on lifetime: 11948 hours (497 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 1f 00 00 00 48 aa b0 40 00
Error: UNC 31 sectors at LBA = 0x0048aab0 = 4762288
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 20 4b be f2 48 aa af 40 00 00:25:21.312 READ DMA
c8 00 00 00 01 00 00 00 4b be f2 43 00 00:25:20.825 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 00:25:20.825 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 00:25:20.825 READ DMA
c8 00 00 1f 01 48 aa b0 00 00 00 40 00 00:25:20.816 READ DMA
Error 116 [115] occurred at disk power-on lifetime: 11948 hours (497 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 1f 00 00 00 48 aa b0 40 00
Error: UNC 31 sectors at LBA = 0x0048aab0 = 4762288
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 20 4b be f2 48 aa af 40 00 00:25:17.192 READ DMA
c8 00 00 00 01 00 00 00 4b be f2 43 00 00:25:17.171 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 00:25:17.171 READ DMA
c8 00 00 00 01 a1 9e 2d 00 00 00 40 00 00:25:17.171 READ DMA
c8 00 00 00 20 00 00 00 a1 9e 0e 40 00 00:25:17.158 READ DMA
Error 115 [114] occurred at disk power-on lifetime: 11948 hours (497 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 7f 00 00 00 48 aa b0 40 00
Error: UNC 127 sectors at LBA = 0x0048aab0 = 4762288
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 80 4b be f2 48 aa af 40 00 00:25:13.499 READ DMA
c8 00 00 00 01 00 00 00 4b be f2 43 00 00:25:13.014 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 00:25:13.014 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 00:25:13.013 READ DMA
c8 00 00 7f 01 48 aa b0 00 00 00 40 00 00:25:13.005 READ DMA
Error 114 [113] occurred at disk power-on lifetime: 11948 hours (497 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 7f 00 00 00 48 aa b0 40 00
Error: UNC 127 sectors at LBA = 0x0048aab0 = 4762288
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 80 4b be f2 48 aa af 40 00 00:25:09.359 READ DMA
c8 00 00 00 01 00 00 00 4b be f2 43 00 00:25:08.870 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 00:25:08.869 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 00:25:08.869 READ DMA
c8 00 00 7f 01 48 aa b0 00 00 00 40 00 00:25:08.861 READ DMA
Error 113 [112] occurred at disk power-on lifetime: 11948 hours (497 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 7f 00 00 00 48 aa b0 40 00
Error: UNC 127 sectors at LBA = 0x0048aab0 = 4762288
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 80 4b be f2 48 aa af 40 00 00:25:05.202 READ DMA
c8 00 00 00 01 00 00 00 4b be f2 43 00 00:25:04.725 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 00:25:04.725 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 00:25:04.725 READ DMA
c8 00 00 7f 01 48 aa b0 00 00 00 40 00 00:25:04.716 READ DMA
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Aborted by host 90% 6720 -
# 2 Extended offline Completed without error 00% 6670 -
# 3 Short offline Completed without error 00% 6669 -
# 4 Extended offline Completed without error 00% 6664 -
# 5 Short offline Completed without error 00% 6664 -
# 6 Extended offline Aborted by host 90% 3655 -
# 7 Short offline Completed without error 00% 3655 -
# 8 Extended offline Aborted by host 90% 2911 -
# 9 Short offline Completed without error 00% 2911 -
#10 Extended offline Aborted by host 90% 2884 -
#11 Extended offline Aborted by host 90% 733 -
#12 Short offline Completed without error 00% 1 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 1 (0x0001)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 44 Celsius
Power Cycle Max Temperature: 46 Celsius
Lifetime Max Temperature: 56 Celsius
SCT Data Table command not supported
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0003 4 0 R_ERR response for device-to-host data FIS
0x0004 4 0 R_ERR response for host-to-device data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x0006 4 0 R_ERR response for device-to-host non-data FIS
0x0007 4 0 R_ERR response for host-to-device non-data FIS
0x0008 4 0 Device-to-host non-data FIS retries
0x0009 4 0 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 2 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC